Product
SJ600C 500MA TV Remote Control  X-ray  Machine
SJ600C 500MA TV Remote Control X-ray Machine
 

SJ600C 500MA TV Remote Control  X-ray  Machine

Product Type: TV REMOTE CONTROL X-RAY MACHINE 
Place of origin: Guangdong
Model No: SJ600C 
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

1 Microcomputer control x-ray radiography assembles: optional 600mA or 50KW.

 

2 Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.

 

3 X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

 

4 Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.
 

 

Department

Technology parameters

 

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

 

Tube voltage

50-110KV continuous voltage

 

Radiography

Tube currency

32-630mA shift

 

Tube voltage

45-125KV continuous voltage

 

Exposure time

0.01-6.3s 23 shift

 

Power

Voltage 

380V±10%

 

Frequency 

50Hz±1Hz

 

Capacity 

≥50KVA

 

Inner resistance

≤0.3Ω

 

X-ray assembly

Focus

1×1.2×2 double focal

 

Rated rotate speed of anode

2800r/min

 

Changed beam limited device

Diagnosis table YS09D

Automatic, adjusted field of view

 

CS15Electro-motion diagnostic table

The table body rotation

"-15°+90°"

 

Focus to film distance

11001500mm,adjustable manual

 

360°foot board

 

The table to height 

870mm

 

Stationary grid

Grid density

40L/cm

 

Grid ration

10:01

 

Focusing distance

120cm

 

Spot film device

Scope of moving

Longitudinal moving:900mm;

 

Transverse moving±120mm

 

Specification of scope film

Full :8"×10",10"×12",11"×14",14"×14"

 

Two: 8"×10",10"×12"

 

Three:11"×14",14"×14"

 

Four: 11"×14",14"×14"

 

Medical television system

configuration

9″x-ray image intensifier made by Toshiba, CCD camera,14″ high resolution monitor

 

14″monitor

resolution

Horizontal center≥1000 TV line

 

Gray scale

≥10 grades

 

Video width

>12MHZ

 

Mode of scan

625 lines,5 field,Interlaced scanning

 

Geometry distortion

<2%

 

SNR

≥40db

 

Power supply

220V 50Hz AC

 

9″x-ray image intensifier made by Toshiba

resolution

≥46LP/mm

 

Conversion modulus

34cd/m2/μGY/s

 

Contrast

10% area:30:1,Φ10mm area18:1

 

CCDJapan Camera

Specification

1/2″,anti-halation,CCIR752×586

 

 

 

 

Option

 

 

 

CDG Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

 

 

Across

±120mm

 

 

 

Mobile beam filtration grid

Grid density

28L/cm

 

 

Grid ratio

8:1

 

 

Focusing distance

100cm

 

 

Scope of moving

≥600mm

 

 

Radiography item

5″×7″,8″×10″,10″×12″,
11″×14″,12″×15″,l14″×14″,
14″×17″

 

Distance from surface to film

75mm

 

Height of bed 

700mm

 

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

 

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

 

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

 

The minimum distance from focal spot

380mm

 

Radiography item

8×10 10×12 11×1412×1514×14 14×17

 

Fixed beam filtration role

Grid density

40L/cm

 

Grid radio

10:1

 

Focal distance

180cm

 

BACK