SD400 Medical X-ray Machine
Product Type: Conventional diagnostic x-ray
Place of origin: Guangdong
Model No: SD400
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY
Features
1) Equipped with double diagnostic table and x-ray rubes, tube voltage is 125kV, tube currency is 400mA, single direct bridge full-wave commutation.
2) X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protecionare provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
3) Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.
4) Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.
5) Applied in all kinds of hospital for radiography such as general body、beam filtration、and chest.
Technology parameters:
Department
|
Technology parameters
|
|
High voltage generator control table and high voltage transform assemble
|
Fluoroscopy
|
Tube currency
|
0.3-5mA continuous currency
|
|
Tube voltage
|
45-110KV continuous voltage
|
|
Radiography
|
Tube currency
|
50-400mA shift
|
|
Tube voltage
|
45-125KV continuous voltage
|
|
Exposure time
|
0.03-5s、23 shift
|
|
Power
|
Voltage
|
380V±10%
|
|
Frequency
|
50Hz±1Hz
|
|
Capacity
|
≥30KVA
|
|
Inner resistance
|
≤0.45Ω
|
|
X-ray assembly
|
Type of x-ray
|
XD51-20.40/125KV
|
|
Focus
|
1×1.2×2 double focal
|
|
Rated rotate speed of anode
|
2800r/min
|
|
Changed beam limited device
|
Diagnosis table YS09D
|
Automatic, adjusted field of view
|
|
Radiograph table YS11S
|
Manually adjusted field of view, luminosity≥100LX
|
|
C15 Diagnostic table
|
Rotate of table
|
-15°~0°~90°automatic
|
|
Moving table
|
Automatic 700mm distance moving lengthways
|
|
Distance of focal table
|
400mm
|
|
High of table
|
820mm
|
|
Spot film device
|
Scope moving
|
Up and down
|
600mm
|
|
Left and right
|
±100mm
|
|
Forward and backward
|
300mm
|
|
Way of locking
|
Electromagnetism locking
|
|
Radiography item
|
5″×7″
|
?
|
?
|
|
|
|
8″×10″
|
?
|
?
|
|
|
|
10″×12″
|
?
|
?
|
?
|
|
|
11″×14″
|
?
|
|
|
|
|
CDGI
Multi function radiography table
|
Moving table
|
Lengthways
|
±600mm
|
Electromagnetism locking
|
Across
|
±120mm
|
Mobile beam filtration grid
|
Grid density
|
28L/cm
|
Grid ratio
|
8:1
|
Focusing distance
|
100cm
|
Scope of moving
|
≥600mm
|
Radiography item
|
5″×7″,8″×10″,10″×12″,11″×14″,
12″×15″,14″×14″,14″×17″
|
Distance from surface to film
|
75mm
|
Height of bed
|
700mm
|
Moving pillar
|
±180°,per 90°orientation, moving lengthways ≥1500mm
|
Bulb tube
|
Rotate the cross arm±180,ascend $ descend 1100mm
|
|
|
|
|
|
|
|
|
|
|
|
|
Option
LSJ pillar radiography frame
|
The scope of ascend and descend
|
1450mm
|
The minimum distance from focal spot
|
380mm
|
Radiography item
|
8"×10" 10"×12" 11"×14"12"×15"
14"×14" 14"×17"
|
Fixed beam filtration role
|
Grid density
|
40L/cm
|
Grid radio
|
10:1
|
Focal distance
|
180cm
|
|