Product
SP001 Wireless Patient Monitoring System
SP001 Wireless Patient Monitoring System
 

SP001 Wireless Patient Monitoring System

Product Type: patient monitor
Place of origin: Guangdong
Model No: SP001
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Carton
Minimum Order: one piece/pieces
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

Description:
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery, remote control.
Optional configuration: 
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module
Respironics-main stream/side stream)-plug&play;
Cardiac Output
Wall Mount for patient monitor ;
Trolly for patient monitor;
12 volts Power supply for ambulance

Accessories for Standard configuration:
1 remote controller
1 set of ECG cable
10 pcs of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff 
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable
1. Displayer:15" color TFT LCD screen with multi-channel waveform display. 
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight 
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5.Easy operation with user friendly menu structure design and rotary dial 
6.Remote control ability for long distance operation.
7.Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
8.Three-application mode: monitoring, diagnosis, operating.
9. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
10.Optional built-in wireless networking function 
11.360 hours data storage.
12. With Drug dose calculation function
13. Intelligent audio and visual comprehensive alarm
14.In-hospital applications include emergency room’s pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
15.Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring.
16.Suitable for adult, pediatrics, neonates

E CG
Input: 5 wires ECG cable 
Lead section:
,,/ aVR, aVL, aVF/ V 
Gain
mm/mV: 1/4,1/2,1,2,4
Sweep speed(mm/sec): 6.25,12.5, 25, 50 
Heart rate range: 15-300 BPM
Heart rate accuracy: ± 1 %
ST segment deviation analysis
NIBP (Non-invasive blood pressure) ()
Measurement type : adult, pediatric, neonatal 
Measurement range: Systolic
  4.0 - 37.0 kPa 
Diastolic 1.3 - 33.0 kPa 
Mean 2.6 - 35.0 kPa
Accuracy : ± 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure 
Tourniquet function

Temperature (surface and rectal)
Measurement range: 25.0 – 45.0

Accuracy: ± 0.1

Resolution: 0.1

response time: ≤ 3 min.

Respiration Rate(RA-LL,RA-LA,LL-LA selectable impedance and nasal cavity) 
Measurement range: 0 - 120 BPM
Accuracy: ± 1 BPM or 5 %
Resolution: 1 BPM
Pulse Rate
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
Pulse measurement range: 30- 250BPM
Accuracy: ± 2 %
Resolution: 1 BPM 

IBP(Invasive blood pressure) (Option)
Measurement range: -1.3~40kPa (-10~300mmHg) 
Channel: 4 channel
Transducer sensitivity: 5MV/V/mmHg 
Unit display: KPa or mmHg selectable

ETCO2 (main/side stream type) (Option) – Plug&Play
Measurement range:0 – 150 mmHg 0 – 19.7% 0 – 20kpa
(Barometric pressure supplied by Host)
Accuracy: 0- 40 mmHg ± 2mmHg
41-70 mmHg ±5% of reading
71-100mmHg±8% of reading
101-150mmHg±10% of reading
Above 80 breath per minute±12% of reading
*NOTE: Gas temperature at 25

Sample rate:50ml/min
Response time:< 3 seconds – includes transport time and rise time 

Cardiac Output
Option
Meathod: thermodilution
Measurement range: CO:0.1-20.0 L/min
TB:23 – 43

TI:0 – 27

Resolution: CO:0.1 L/min
TI:0.1

TB:0.1

Accuracy: CO: ± 0.2 L/min or ±5%
TB: ± 0.2

TI: ± 0.2

Parameter output:
Cardiac output Hemodynamics calculation
Power requirements 
Input: 100
240 V AC, 50/60Hz
Consumption: ≤ 80VA
Environment
        Operation  Storage
Temperature 0.5 - 40
 -20 - 50
Relative humidity ≤ 80% 
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003