Product Type: patient monitor
Place of origin: guangzhou
Model No: S-8000A
Price Terms: FOB Guangzhou
Payment Terms: T/T,Western Union,MoneyGram
Package: carton
Minimum Order: 1 set
Delivery Time: 15 days after payment
Brand Name: SUNNY

Features of the 7 inch patient monitor:
4 Standard parameters: ECG, NIBP, SpO2, RESP. These four parameters are flexible. You 
can choose any parameters what you need. 
7 inch high resolution color TFT LCD display.
Real time S-T segment analysis, pace-maker detection.
Indication of Incorrect manipulation and malfunction analysis.
Patient info input management function
Multi-lead ECG waveforms display in phase.
Large volume of tabular and graphic trends information storage and easy to recall.
Capture dynamic waveforms.
Efficient resistance to interference of defibrillator and HF knife.
UP to 4 hours working capacity of built-in rechargeable battery.
Unique accessory management cabinet.
Networking capacity.
Rechargeable Lithium battery
Suitable for adult,pediatrics and neonate patients.

Detail information of the 7 inch patient monitor : 

 

RESP 
Measuring Method
RA-LL impedance
RESP Impedance Measuring Range 0.3~3Ω
Base Impedance Range 200~4000Ω
Bandwidth 0.1~2.5Hz
RESP Rate
Range
Adult       0~120BrPM
Children and neonatal baby   0~150 BrPM
Resolution            1 BrPM
Precision            2 BrPM
Asphyxia Alarm 10~40 seconds


NIBP 
Measuring Method Pulse wave oscillometry 
Work Mode Manual/Automatic/STAT
Measuring Interval of Automatic Measuring Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode 5 minutes
PR range 40 – 240 bpm
Measuring Range and Precision


Range
Adult  Systolic blood pressure    40~270mmHg
         Diastolic blood pressure    10~215mmHg
         Mean blood pressure        20~235mmHg
Children  Systolic blood pressure  40~200mmHg
        Diastolic blood pressure    10~150mmHg
        Mean blood pressure        20~165mmHg
  Neonatal baby Systolic blood pressure  40~135mmHg
        Diastolic blood pressure    10~100mmHg
        Mean blood pressure        20~110mmHg
Static pressure range     0~300mmHg
Static pressure precision  3mmHg
Pressure precision:    Max. average error: 5mmHg;Max. 
standard deviation: 8mmHg

Overvoltage protection
Adult mode            300 mmHg
Children mode            240 mmHg
Neonatal baby mode    150 mmHg
SpO2 
Range            0~100%
Resolution      1%
Precision 70~100%:2 DIGIT 0%~69%:no definition given

PR
Range            20~300bpm
Resolution      1bpm
Precision          3bpm

 

ECG
Lead configuration
Standard 3-lead or 5-lead 
3-lead  RA,LA,LL,Lead method:I,II,III
5-lead  RA,LA,LL,RL,V,Lead method:I,II,III,aVR,aVL,aVF,V
Increase
    250,500,1000,2000

HR
Range
       Adult                     15 ~ 300bpm (beat/minute)
       Neonatal baby/children         15 ~ 350 bpm(beat/minute)
Precision      ±1% or ±1bpm,the larger prevails
Resolution       1 bpm(beat/minute)
Sensitivity  > 200 uV (Peak-to-peak value)
Input Impedance > 5 (megohm)

Bandwidth
Diagnostic mode    0.05~130Hz
Monitoring Mode      0.5~40Hz
Operation mode    1~20Hz
Common Mode rejection Ratio
Diagnostic mode    > 90 dB
Monitoring Mode      > 100 dB
Operation mode    > 100 dB
Pole Polarization Vvoltage Range 300Mv
Pacing Pulse Test
Test pacing pulse in accordance with the following conditions:
Amplitude:    ±2 mV ~ ±700mV
Width:        0.1ms ~ 2ms
Risetime:        10us~100µs
Pacing pulse inhibition
When pacing analysis switch is on, pacing pulse in accordance with the following 
conditions are restrained, but affection against HR calculation. 
Amplitude:    ±2 mV ~ ±700mV
Width:       0.1ms ~ 2ms
Risetime:       10us ~ 100µs
Baseline Recovering Time
After defibrillation< 3 seconds 
Signal Range 8 mV (Peak-to-peak value)


Calibrating Signal
1mV(Peak-to-peak value),precision  5% 
ST Segment Measuring Volume
Measuring range: -2.0mV ~ +2.0mV
Measuring precision: Ranging -0.8 mV~+0.8mV, measuring error is ±0.02mV or ±10%,. 
The larger prevails.
No definition for other ranges.

 


Standard Configuration: ECG, NIBP, SpO2, RESP
Optional:  ETCO2    Thermal recorder  Wall mount  Trolley 