S9000A Multi Parameter Patient Monitor
S9000A Multi Parameter Patient Monitor
 

S9000A Multi Parameter Patient Monitor

Product Type: patient monitor
Place of origin: Guangdong
Model No: S9000A
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Carton
Minimum Order: one piece/pieces
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

 

 

 

ECG measurement

 

Leads choices:

All, I, II, III, aVF, aVR, aVL V1--6 chest leads showed.

Gains options:

× 1, × 2, × 4, and × 0.5 four trenches

Frequency:

0.5 Hz - 100 Hz

Common-mode signal inhibition:

More than 70 dB

Scan rate:

12.5 mm/ S, 25 mm / S, 50 mm / S standard three stalls.

HR:

± 5 bpm

Precision calibration signal:

1mv(peak, ± 3% accuracy)

ST Detection:

Measurement range(-1.0mV----+1.0mV)

Using Standard:

meet the ANSI / AMI EC13 -1992 standard

Response time:

1s

Alarm:

Sound and Light

Preset heart rate range:

(Alarm over preset numerical)

Ceiling:

1-255 bpm adjustable

Threshold:

0-254 bpm adjustable

RESP Breath

 

Breathing frequency range:

0-60 bum

Accuracy:

± 1brpm

Response time:

1s

Gains options:

× 1, × 2, × 4, and × 0.5 four trenches

Alarm:

Sound and Light

Alarm range:

(numerical preset alarm over)

Ceiling:

10-100 bpm adjustable

Threshold:

0 -99 bpm adjustable

NIBP measurement

 

Technology:

Oscillometric

Mode:

manual / automatic

Measurement units:

mmHg / kpa

Protection:

Double security protection

A measurement time:

less than 45 S

Scope:

Pressure Cuffs 0-250 mmHg

Blood pressure
measurement accuracy:

ANSI /AAMI, SP10-1992 standard error and standard
deviation of the average value of the initial

Inflatable cuffs:

180 mmHg (120 mmHg children newborn 70 mmHg)

Inflatable cuffs follow:

original SBP: + 30 mmHg

Blood pressure
measuring range:

Systolic blood pressure: 60-250 mmHg

Diastolic blood pressure: 40-220 mmHg

Pressure on the average: 45-235 mmHg

Response time:

1s

Alarm:

Sound and Light

Preset range:

report (Numerical exceed preset alarm)

Systolic blood pressure maximum:

1-255 mmHg adjustable

Threshold:

0-254 mmHg adjustable

Diastolic blood pressure ceiling:

1 -255 mmHg adjustable

Minimum standards:

0 -254 mmHg adjustable

Use standard:

compliance with the ANSI / AAMI SP10-1992 standard

 

 

Spo2 measurement

 

Range:

0-100%

Accuracy:

1%

Resolution:

1%

Pulse frequency:

20-250 times / min

Response time:

1s

Alarm:

Sound and Light

Preset range:

report (Alarm over preset numerical)

Ceiling:

1% - 100% adjustable

Threshold:

0% - 99% adjustable

TEMP measurement:

 

Technology:

thermostat temperature probe

Measuring range:

20 ° C-45 ° C

Temperature resolution:

0.10%

Accuracy:

± 1 ° C

Response Time:

1s

Alarm:

Sound and Light

Preset range:

report (numerical preset alarm over)

Maximum:

20.1 ° C-45.5 ° C adjustable

Threshold:

20 ° C-45.4 ° C Adjustable

Trend Graph:

 

Types

Graphical /tabular

Memory storage:

48 hours (not restart preservation)

Data interval:

30 seconds

Graphic form:

one graph per channel.

Tabular form:

graphics are the parameters with 11 per trip
(and time parameters). One page 15 firms external

Power

 

AC power supply:

AC 180-220V, 50Hz-60Hz. 1A maximum current

Temperature:

0-40 ° C

Storage temperature:

-20 °C-50°C

Working humidity: g

5-95% relative humidity, non-condensin

Humidity storage:

5-95% relative humidity, non-condensing

Altitude:

0-1000 feet (working condition)

Whole Power:

not more than 40W