Product
SD400R(CDG) Medical  X-ray  Machine
SD400R(CDG) Medical X-ray Machine
 

SD400R(CDG) Medical  X-ray  Machine

Product Type: Conventional diagnostic x-ray 
Place of origin: Guangdong
Model No: SD400R(CDG)
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

1 Equipped with single diagnostic table and x-ray rubes, single direct bridge full-wave commutation, tube voltage is 125kV, tube currency is 400mA.

 

2 X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

 

3 Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.

 

4 Radiography table can move lengthways and crossover,can loaded all kinds of radiography dark box, use conveniently and it is beautiful.

 

5 Applied in all kinds of hospital for radiography such as general bod ,beam filtration,and chest.


 

 

Department

Technology parameters

 

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

 

Tube voltage

45-110KV continuous voltage

 

Radiography

Tube currency

50-400mA shift

 

Tube voltage

45-125KV continuous voltage

 

Exposure time

0.03-5s,23 shift

 

Power

Voltage

380V±10%

 

Frequency

50Hz±1Hz

 

Capacity

≥30KVA

 

Inner resistance

≤0.3Ω

 

X-ray assembly

Type of x-ray

XD51-20.40/125

 

Focus

1×1.2×2 double focal

 

Rated rotate speed of anode

2800r/min

 

CDG

Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

81

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5″×7″,8″×10″,10″×12″,11″×14″,12″×15″,14″×14″,14″×17″

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180ascend $ descend 1100mm

Option

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8"×10 10×12 11×1412×15

14×14 14×17

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:1

Focal distance

180cm

BACK