Product
SD400 Medical X-ray  Machine
SD400 Medical X-ray Machine
 

SD400 Medical X-ray  Machine

Product Type: Conventional diagnostic x-ray 
Place of origin: Guangdong
Model No: SD400
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

Features
 1 Equipped with double diagnostic table and x-ray rubes, tube voltage is 125kV, tube currency is 400mA, single direct bridge full-wave commutation.

2 X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protecionare provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

3 Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.

4 Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.

5 Applied in all kinds of hospital for radiography such as general bodybeam filtrationand chest.

 

Technology parameters:

Department

Technology parameters

 

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

 

Tube voltage

45-110KV continuous voltage

 

Radiography

Tube currency

50-400mA shift

 

Tube voltage

45-125KV continuous voltage

 

Exposure time

0.03-5s23 shift

 

Power

Voltage

380V±10%

 

Frequency

50Hz±1Hz

 

Capacity

≥30KVA

 

Inner resistance

≤0.45Ω

 

X-ray assembly

Type of x-ray

XD51-20.40/125KV

 

Focus

1×1.2×2 double focal

 

Rated rotate speed of anode

2800r/min

 

Changed beam limited device

Diagnosis table YS09D

Automatic, adjusted field of view

 

Radiograph table YS11S

Manually adjusted field of view, luminosity≥100LX

 

C15 Diagnostic table

Rotate of table

-15°~0°~90°automatic

 

Moving table

Automatic 700mm distance moving lengthways

 

Distance of focal table

400mm

 

High of table

820mm

 

Spot film device

Scope moving

Up and down

600mm

 

Left and right

±100mm

 

Forward and backward

300mm

 

Way of locking

Electromagnetism locking

 

Radiography item

5″×7″

?

?

 

 

 

8″×10″

?

?

 

 

 

10″×12″

?

?

?

 

 

11″×14″

?

 

 

 

 

CDGI

Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

81

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5″×7″8″×10″,10″×12″,11″×14″,

12″×15″,14″×14″,14″×17″

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180ascend $ descend 1100mm

Option

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8"×1010×12 11×1412×15

14×14 14×17

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:1

Focal distance

180cm

BACK