Product
SB500R(CDGI)  Medical x-ray machine
SB500R(CDGI) Medical x-ray machine
 

SB500R(CDGI)  Medical x-ray machine

Product Type: Conventional diagnostic x-ray 
Place of origin: Guangdong
Model No: SB500R(CDGI)
Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

1 Equipped with single diagnostic table and x-ray rubes, single direct bridge full-wave commutation, tube voltage is 125kV, tube currency is 500mA.


2
Total 540 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.


3
X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.


4
Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.


5
Applied in all kinds of hospital for radiography such as general body,beam filtration,and chest.
 

Department

Technology parameters

High voltage generator control table and high voltage transform assemble

Power

Voltage

380V±10%

Capacity

50Hz±1Hz

Frequency

≥32KVA

Inner resistance

≤0.3Ω

Tube voltage

45-125kV step 1kV

Tube currency

30-500mA 8 shift

Exposure time

0.01-5.0S 25 shift

Max rated capacity

mA

600

500

400

500

400

kV

71

84

106

84

106

X-ray assembly

Type of x-ray

XD52-30.50/125

Focus

1×1.2×2 double focal

Rated rotate speed of anode

2800r/min

Manually beam limited device

Model

Manually continuous adjusted field of

Field view

View, luminosity≥100LX,1minlimit-time device

CDGI

Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

81

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5″×7″,8″×10″,10″×12″,11″×14″,12″×15″,14″×14″,14″×17″

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

Option

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8"×10 10×12 11×1412×15

14×14 14×17

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:1

Focal distance

180cm

BACK