Product
S300A Medical  X-ray  Machine
S300A Medical X-ray Machine
 

S300A Medical X-ray Machine

Product Type: Conventional diagnostic x-ray
Place of origin: Guangdong
Model No: S300A

Price Terms: FOB Guangzhou
Payment Terms: T/T.L/C.Western Union.MoneyGram
Package: Wooden case
Minimum Order: One set/sets
Delivery Time: 15 days after receive payment
Brand Name: SUNNY

Use

General radiograph,Filter-ray-filter radiograph

Unit Configuration

Control, HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column ,Collimator

Main Characteristics

1. Single-table/single-tube

2. Rotary anode X-ray tube unit and tangential annular tube head

3. Single-phase full wave rectification high-voltage generator

4. Power voltage(v) radiograph kilovolt (KV).step-less control electric mechanism

5. Filament stabilizer for X-ray tube unit and space charge compel mentor

6. Radiograph volume KV ,mA and S. grading and interlock protection

7. Adopt digital circuit timer. Grading according to R10 priority coefficient,(for more accurately controlling time)

8.HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power

9. Radiographic table can move in length an breadth

10.The radiographic table. Column and vibrating grid are in a whole without ceiling and floorh rails bottom

Min Technical Indexes

ITEM

CONTENTS

INDEX

Demand of power supply

Capacity

Two-phase 30KVA

Voltage,Frequency

380V/220V ±1050HZ ±0.5Hz

Intemal resistance

2Ω(380V) 0.6 Ω(220V)

power supply

Adjustable range

380±10% at220V being adjustable continuously

Radiograph

Voltage

50-90KV 50-90KV being adjustable continuously

current

Small focus:50mA100mA,Big focus:50mA 100mA 200mA 300mA

time

0.04~6.35s 23grades together grading a according to R10 coefficient

High-voltage generator

Capacity

20KVAinstantaneous

Max DC output voltage

125KV

Max DC output current

300mA

X-Ray tube

Model

XD51.20-40/125

Focus

Small focus 1×1mm big focus2×2mm

Radiographic table

Length×width×height of bed surface

2000mm×665mm×700mm

Moving range of bed surface

640mm in Length,200mmin breadth

Ray-filter of table

Travel in length ≥500mm

Grid density N=28

Convergence distance f=100cm

Grid ratio r=8

Column of X-ray tube unit

Moving Longitudinally along

Radiographic table

1000mm or 1800mm

Distance to friend as moving up and down (along column)

650~1800mm

Rotary around the center of cross arm

±180°

Rotary around the shaft line of

X-ray annular tubes

-10°~60°~ +120°

Max size of cassette

356mm×432mm (14″×17″)

Note: We will not make another notice if the contour of product and technical parameters will be changed

 